#141 Acronis Backup:恢复到VMWare新虚拟机失败,显示“Invalid configuration for device '0'”

iconRemoved User在 2020-4-14 下午2:33 编写 ( icon王兴达在 2024-4-3 下午5:43 更新 <历史> )
  编辑(登录)
  收藏
  响应调查   响应调查

  主题

问题现象(介绍)

  1. 使用VMWare代理(Windows)或Appliance虚拟设备将VM备份恢复到ESXi 6.7上的新虚拟机。
  2. 活动失败,并显示以下错误:
    Invalid configuration for device '0'

完整错误日志:

| error 0x728064: Failed to recover the entire virtual machine.
| line: 0x2b2c9ed481007be6
| file: e:/422/enterprise/migration/impl/manager_group_restore.cpp:350
| function: RestoreEntireVm
| $module: disk_bundle_tape_off_glxa64_13400
|
| error 0x728014: Failed to recover virtual machine 'test' with ID 'vm:28E86ABC-553A-D018-9855-B0036E997245?type%3dvmwesx'.
| line: 0x28314c961de7d979
| file: e:/422/enterprise/migration/impl/manager_vmbackup.cpp:3210
| function: RestoreInternalNew
| $module: disk_bundle_tape_off_glxa64_13400
|
| error 0x530079: Failed to create virtual machine '[datastore1]' from the configured template.
| line: 0xa859dd78cc91e21b
| file: e:/422/enterprise/virtualware/raw/vmware/server/esx_srv_lib/esx_vm.cpp:1689
| function: CreateObject
| $module: esx_srv_glxa64_13400
|
| error 0x530128: Invalid configuration for device '0'.
| line: 0xc7610e0a857bede2
| file: e:/422/enterprise/virtualware/raw/vmware/vix_soap/vix_supp_impl.cpp:362
| function: WaitForTaskResult
| fault: MethodFault
| $module: esx_srv_glxa64_13400

问题原因

产品中的问题,该问题将在下次更新中修复。

解决方法

在问题修复前的解决方法,创建一个具有与原始VM相同的磁盘结构的空虚拟机,并使用可启动媒体恢复备份:

  1. 创建可启动媒体
  2. 使用创建的可启动媒体引导启动新虚拟机;
  3. 按照产品文档中的恢复说明进行操作:请参阅使用可启动媒体恢复磁盘

原文链接:https://kb.acronis.com/content/63373

 附加文件     - [0]